ORION Recovery Rigel — Cold Therapy

RIGEL — COLD THERAPY

Make room for cold.

Cold plunges within ORION Recovery.

Explore integrated plunges and separate chiller systems. Compare the model’s format, temperature range, controls and documented heating or cooling capability.

Cold, with a clear place.

Rigel expresses the cold side of ORION. A focused visual language connects the plunge, its surrounding equipment and the setting.

Water and material study.

Explore Rigel cold plunges.

Rigel includes integrated plunge models and systems with a separate chiller. Cooling-only and heating/cooling configurations are distinct; choose using the specification for the exact model.

Integrated plunges

The G3 combines a long tub format with six built-in jets. The G4 uses a compact upright format. Both models explicitly list cooling and heating.

Cooling-only chillers

The XY-03-0C and XY-06-0C catalogue pages identify these as cooling-only units. Their chiller specifications are not tub specifications.

Heating and cooling systems

XY PRO and SY PRO are documented heating/cooling chiller lines. Capacity, temperature range and electrical requirements must be matched to the chosen variant.

G3 · YG-10-G3All-in-one plunge · 1HP

An integrated plunge with a built-in six-jet massage system. The catalogue documents both cooling and heating for this model.

G3 · YG-10-G3 specifications
Chiller model1HP
FunctionsCooling; heating (HC)
Adjustable water temperature3–42°C
Product dimensions200 × 80 × 80 CM
Net weight135KG
Colours listedBlack / White
Power supply — 220–240V version220–240V, 50/60Hz
Maximum input current — 220–240V version6.5A
Filtration and sanitationInternally mounted filter; built-in ozone generator
Water systemBuilt-in circulation pump; 24V DC water pump; built-in six-jet massage system
Controls5-inch dot matrix screen; iOS & Android APP / WIFI
SettingIndoor and outdoor cooling and heating
G4 · YG-10-G4All-in-one plunge · 1HP

A compact upright format with a shorter footprint than the G3. Its catalogue also documents both cooling and heating.

G4 · YG-10-G4 specifications
Chiller model1HP
FunctionsCooling and heating
Water temperature3–42°C
Product dimensions1200 × 950 × 1000 mm
Power supply options listed100–127V / 220–240V, 50/60Hz
Filtration and sanitationBuilt-in filter; ozone disinfection
ControlsiOS & Android APP, WIFI
RefrigerantR410A

The G3 figures above use its 220–240V electrical configuration. The G4 catalogue lists alternative power supplies; the supplied version must be confirmed. Neither model’s listed dimensions are a statement of usable water capacity.

Match the system to the model.

For a separate chiller setup, confirm the tub, chiller code, power-supply variant, hoses, filtration and any optional components as one configuration. A photo of a tub beside a chiller does not establish which accessories are included.

For the integrated G3 and G4, filtration, controls and temperature ranges are listed above. Water capacity, shell materials, insulation and accessory inclusions need to be confirmed for the selected configuration.

Consider the setting.

Think about the plunge’s position, access and the space around it. Share a plan or reference image if you have one.

Begin with Rigel.

Share what you have in mind for cold and the environment around it.